E0104 HORIZONTAL IONIZING AIR BLOWER, On the base of design of E0105 horizontal ioni-zing air blower, it is smaller and more portable.Can install ionizing equilibrium measurement realtime supervising and alarming system as request.The ionizing air volume can be adjusted, including high voltage generator
Specification:
| Operating Voltage | 110V/60HZ OR 220V/50HZ |
| Current Consumption | 3.0A OR 1.5A |
| Operating Temperature | -10~50℃ |
| Size | 400mm(L)×220mm(W)×190mm(H) |
| Weight | 5.8Kg |
| Air Volume | 70~120CFM |
| Ion Balance | 0V±10V |
| Air Coverage | 60cm×120cm |
Decay tdst Results:
| Testing
Conditions |
Test voltage:1KV-100V Operating Voltage:110/220V Temperature:22℃ Test Humidity:75%RH | |||
| Distance | 300mm | 600mm | 900mm | 1200mm |
| Left300mm | 1.3s | 2.5s | 3.9s | 6.6s |
| Center | 1.1s | 2.2s | 3.6s | 6.5s |
| Right300mm | 1.2s | 2.3s | 3.8 | 6.3s |
















Reviews